Products

12/20(24)kV CU XLPE AWA/SWA PVC Armoured Cable

Review the construction and specification data below to compare this cable with your project requirements.

01 / Construction & ratings

Construction & ratings

  • 0.7: Soil condition: Very wet; Meteorological condition: Continuous rainfall
  • 1.0: Soil condition: Wet; Meteorological condition: Normal rainfall
  • 2.0: Soil condition: Dry; Meteorological condition: Infrequent rainfall
  • 3.0: Soil condition: Very dry; Meteorological condition: Rare or no rainfall
12/20(24)kV  CU XLPE AWA/SWA PVC Armoured Cable12/20(24)kV  CU XLPE AWA/SWA PVC Armoured Cable

02 / Technical data

Technical data

Product identifiers, units and manufacturer specification data are kept in their original form.

12/20(24)kV CU XLPE AWA/SWA PVC Armoured Cable · 01
Model CodeCross-sectionConductor DiameterNominal Insulation ThicknessApprox. Outer Diameter of CableApprox. Cable Weight
mm²mmmmmmkg/km
YJV72-12/20kV1*356.625.530.051742.8
YJV72-12/20kV1*507.655.531.251933.7
YJV72-12/20kV1*709.215.533.782457.7
YJV72-12/20kV1*9510.785.535.352821.9
YJV72-12/20kV1*12012.125.536.863153.1
YJV72-12/20kV1*15013.695.538.433504.9
YJV72-12/20kV1*18515.215.540.123949.2
YJV72-12/20kV1*24017.405.542.314634.8
YJV72-12/20kV1*30019.555.545.975763.3
YJV72-12/20kV1*40022.055.548.646725.5
YJV72-12/20kV1*50025.005.552.738094.0
YJV72-12/20kV1*63028.405.556.479692.9
YJV72-12/20kV1*80033.705.561.9411899.8
YJV32-12/20kV3*356.625.557.575539.3
YJV32-12/20kV3*507.655.560.146181.6
YJV32-12/20kV3*709.215.563.687119.6
YJV32-12/20kV3*9510.785.567.418326.2
YJV32-12/20kV3*12012.125.571.9910223.2
YJV32-12/20kV3*15013.695.575.5511406.4
YJV32-12/20kV3*18515.215.579.1812888.2
YJV32-12/20kV3*24017.405.584.4215218.8
YJV32-12/20kV3*30019.555.589.4017653.5
YJV32-12/20kV3*40022.055.595.4820730.6
YJV32-12/20kV3*50025.005.5104.0924803.6
YJV32-12/20kV3*63028.405.5113.6431446.8
12/20(24)kV CU XLPE AWA/SWA PVC Armoured Cable · 02
Cross-sectionMax. Coductor DC Resistance at 20 ℃Max. Coductor AC Resistance at 90 ℃CapacitanceFault Current CapacityPositive and Negative Sequence ImpedanceZero-sequence impedance (single-end grounded
ConductorMetallic ScreenTrefoilFlatTrefoilFlat
mm²Ω/kmΩ/kmμF/kmkA/1skA/1sΩ/kmΩ/kmΩ/kmΩ/km
1×350.5240.6680.16325.10.730.668+j0.1590.668+j0.2170.816+j0.7930.816+j0.706
1×500.3870.4940.17667.30.730.494+j0.1490.494+j0.2080.642+j0.7770.642+j0.690
1×700.2680.3420.197710.20.730.342+j0.1430.342+j0.2010.490+j0.7590.490+j0.672
1×950.1930.2460.220013.80.730.247+j0.1360.246+j0.1940.394+j0.7430.394+j0.656
1×1200.1530.1960.236917.40.730.196+j0.1320.196+j0.1900.344+j0.7300.343+j0.643
1×1500.1240.1590.255121.80.730.159+j0.1290.159+j0.1870.307+j0.7140.307+j0.627
1×1850.09910.12710.275826.80.730.127+j0.1260.127+j0.1840.275+j0.7020.275+j0.615
1×2400.07540.09720.304134.70.730.097+j0.1210.097+j0.1790.245+j0.6860.245+j0.599
1×3000.06010.07790.331043.40.730.078+j0.1180.078+j0.1760.226+j0.6720.226+j0.585
1×4000.04700.06160.363057.80.730.062+j0.1130.061+j0.1710.210+j0.6550.209+j0.568
1×5000.03660.04880.402672.20.730.049+j0.1100.049+j0.1680.197+j0.6390.197+j0.552
1×6300.02830.03880.445990.80.730.040+j0.1070.039+j0.1650.188+j0.6230.187+j0.536
1×8000.02210.03160.5196115.30.730.033+j0.1060.031+j0.1650.181+j0.6020.179+j0.515
12/20(24)kV CU XLPE AWA/SWA PVC Armoured Cable · 03
Cross-sectionMax. Coductor DC Resistance at 20 ℃Max. Coductor AC Resistance at 90 ℃CapacitanceInductanceImpedanceFault Current CapacityPositive and Negative Sequence ImpedanceZero-sequence impedance (single-end grounded )
ConductorMetallic Screen
mm²Ω/kmΩ/kmμF/kmmH/kmΩ/kmkA/1skA/1sΩ/kmΩ/km
3×350.5240.6680.16320.47150.68455.11.920.668+j0.1390.817+j0.832
3×500.3870.4940.17660.45260.51387.31.920.494+j0.1310.642+j0.815
3×700.2680.3420.19770.41980.366610.21.920.342+j0.1250.490+j0.796
3×950.1930.2470.22000.39980.276713.81.920.247+j0.1190.395+j0.777
3×1200.1530.1960.23690.38720.230517.41.920.196+j0.1150.344+j0.764
3×1500.1240.1590.25510.37320.197521.81.920.159+j0.1110.307+j0.750
3×1850.09910.12760.27580.36210.170926.81.920.127+j0.1080.276+j0.737
3×2400.07540.09780.30410.34930.146934.71.920.098+j0.1040.246+j0.720
3×3000.06010.07880.33100.33790.132143.41.920.079+j0.1010.227+j0.704
3×4000.04700.06280.36300.32790.120657.81.920.063+j0.0970.211+j0.687
3×5000.03660.05040.40260.31030.109672.21.920.050+j0.0950.198+j0.669
3×6300.02830.04090.44590.29840.102290.81.920.041+j0.0930.189+j0.652
12/20(24)kV CU XLPE AWA/SWA PVC Armoured Cable · 04
Conductor operating temperature ( ℃ )Temperature  in air ( ℃ )
2025303540455055
901.211.161.111.061.000.940.880.81
12/20(24)kV CU XLPE AWA/SWA PVC Armoured Cable · 05
Conductor operating temperature ( ℃ )Temperature in soil ( ℃ )
101520253035
901.111.071.041.000.960.92
12/20(24)kV CU XLPE AWA/SWA PVC Armoured Cable · 06
Conductor operating temperature ( ℃ )Soil thermal resistivity (K·m/W)  -direct burial
0.711.21.522.53
901.131.000.930.860.760.690.64
12/20(24)kV CU XLPE AWA/SWA PVC Armoured Cable · 07
Conductor operating temperature ( ℃ )Soil thermal resistivity (K·m/W)  -conduit burial
0.711.21.522.53
901.081.000.960.900.820.770.72
12/20(24)kV CU XLPE AWA/SWA PVC Armoured Cable · 08
Conductor operating temperature ( ℃ ) )Burial depth in soil (m) -direct burial
0.50.71.01.52.02.5
901.071.031.000.960.940.92
12/20(24)kV CU XLPE AWA/SWA PVC Armoured Cable · 09
Conductor operating temperature ( ℃ )Burial depth in soil (m) – in conduit
0.50.71.01.52.02.5
901.041.021.000.980.960.95

Before you specify

What information should I include in an inquiry?

Include the product designation, operating voltage, conductor size, number of cores, required length and delivery destination. Add installation conditions and any required standard.

Can I use these tables to make the final cable selection?

Use the published values to compare products. Confirm the final construction, current rating and installation requirements with your project engineer and the supplier.

How can I keep a copy of this specification?

Use Print / Save PDF on this page. The print layout includes the product name, construction details and specification tables.

Can the team review a project specification?

Send your requirements through the inquiry form. Include the relevant drawings or document references in your message so the team can follow up.

Related cables

Contact us

Bring your next connection into focus.

Share your application, working voltage, cable size and destination. Our team can help you identify the next step.

Discuss a project

Tell us what you are planning.

Your details are used to respond to this inquiry. Privacy