01 / Construction & ratings
Construction & ratings
- IEC 61089 Round Wire Concentric Lay Overhead Electrical Stranded Conductors
- ASTM B 399 Concentric-Lay-Stranded Aluminum-Alloy 6201-T81 Conductors.
- BS EN 50182 Conductors for Overhead Lines-Round Wire Concentric Lay stranded Conductors
- AS 1531 Conductors – Bare Overhead – Aluminum and Aluminum Alloy
- GB/T 1179 Round Wire Concentric Lay Overhead Electrical Stranded Conductors
02 / Technical data
Technical data
Product identifiers, units and manufacturer specification data are kept in their original form.
| AAAC/A2 | |||||||
|---|---|---|---|---|---|---|---|
| Code Number | Area | No.of Wires | Diameter | Linear Mass | Rated Strength | D.C. Resistance | |
| Wire | Cond. | ||||||
| mm 2 | mm | mm | kg/km | kN | Ω/km | ||
| 16 | 18.4 | 7 | 1.83 | 5.49 | 50.4 | 5.43 | 1.7896 |
| 25 | 28.8 | 7 | 2.29 | 6.86 | 78.7 | 8.49 | 1.1453 |
| 40 | 46 | 7 | 2.89 | 8.68 | 125.9 | 13.58 | 0.7158 |
| 63 | 72.5 | 7 | 3.63 | 10.9 | 198.3 | 21.39 | 0.4545 |
| 100 | 115 | 19 | 2.78 | 13.9 | 316.3 | 33.95 | 0.2877 |
| 125 | 144 | 19 | 3.1 | 15.5 | 395.4 | 42.44 | 0.2302 |
| 160 | 184 | 19 | 3.51 | 17.6 | 506.1 | 54.32 | 0.1798 |
| 200 | 230 | 19 | 3.93 | 19.6 | 632.7 | 67.91 | 0.1439 |
| 250 | 288 | 19 | 4.39 | 22 | 790.8 | 84.88 | 0.1151 |
| 315 | 363 | 37 | 3.53 | 24.7 | 998.9 | 106.95 | 0.0916 |
| 400 | 460 | 37 | 3.98 | 27.9 | 1268.4 | 135.81 | 0.0721 |
| 450 | 518 | 37 | 4.22 | 29.6 | 1426.9 | 152.79 | 0.0641 |
| 500 | 575 | 37 | 4.45 | 31.2 | 1585.5 | 169.76 | 0.0577 |
| 560 | 645 | 61 | 3.67 | 33 | 1778.4 | 190.14 | 0.0516 |
| 630 | 725 | 61 | 3.89 | 35 | 2000.7 | 213.9 | 0.0458 |
| 710 | 817 | 61 | 4.13 | 37.2 | 2254.8 | 241.07 | 0.0407 |
| 800 | 921 | 61 | 4.38 | 39.5 | 2540.6 | 271.62 | 0.0361 |
| 900 | 1036 | 91 | 3.81 | 41.8 | 2861.1 | 305.58 | 0.0321 |
| 1000 | 1151 | 91 | 4.01 | 44.1 | 3179 | 339.53 | 0.0289 |
| 1120 | 1289 | 91 | 4.25 | 46.7 | 3560.5 | 380.27 | 0.0258 |
| 1250 | 1439 | 91 | 4.49 | 49.4 | 3973.7 | 424.41 | 0.0231 |
| AAAC/A3 | |||||||
| Code Number | Area | No.of Wires | Diameter | Linear Mass | Rated Strength | D.C. Resistance | |
| Wire | Cond. | ||||||
| mm 2 | mm | mm | kg/km | kN | Ω/km | ||
| 16 | 18.6 | 7 | 1.84 | 5.52 | 50.8 | 6.04 | 1.7896 |
| 25 | 29 | 7 | 2.3 | 6.9 | 79.5 | 9.44 | 1.1453 |
| 40 | 46.5 | 7 | 2.91 | 8.72 | 127.1 | 15.1 | 0.7158 |
| 63 | 73.2 | 7 | 3.65 | 10.9 | 200.2 | 23.06 | 0.4545 |
| 100 | 116 | 19 | 2.79 | 14 | 319.3 | 37.76 | 0.2877 |
| 125 | 145 | 19 | 3.12 | 15.6 | 399.2 | 47.2 | 0.2302 |
| 160 | 186 | 19 | 3.53 | 17.6 | 511 | 58.56 | 0.1798 |
| 200 | 232 | 19 | 3.95 | 19.7 | 638.7 | 73.2 | 0.1439 |
| 250 | 290 | 19 | 4.41 | 22.1 | 798.4 | 91.5 | 0.1151 |
| 315 | 366 | 37 | 3.55 | 24.8 | 1008.4 | 115.29 | 0.0916 |
| 400 | 465 | 37 | 4 | 28 | 1280.5 | 146.4 | 0.0721 |
| 450 | 523 | 37 | 4.24 | 29.7 | 1440.5 | 164.7 | 0.0641 |
| 500 | 581 | 37 | 4.47 | 31.3 | 1600.6 | 183 | 0.0577 |
| 560 | 651 | 61 | 3.69 | 33.2 | 1795.3 | 204.96 | 0.0516 |
| 630 | 732 | 61 | 3.91 | 35.2 | 2019.8 | 230.58 | 0.0458 |
| 710 | 825 | 61 | 4.15 | 37.3 | 2276.2 | 259.86 | 0.0407 |
| 800 | 930 | 61 | 4.4 | 39.6 | 2564.8 | 292.8 | 0.0361 |
| 900 | 1046 | 91 | 3.83 | 42.1 | 2888.3 | 329.4 | 0.0321 |
| 1000 | 1162 | 91 | 4.03 | 44.4 | 3209.3 | 366 | 0.0289 |
| 1120 | 1301 | 91 | 4.27 | 46.9 | 3594.4 | 409.92 | 0.0258 |
| AAAC | ||||||
|---|---|---|---|---|---|---|
| Conductor Size | No. and Diameter | Overall Diameter | Mass | Rated Strength | Nominal DC Resistance at 20℃ | |
| AWG or MCM | mm² | mm | mm | kg/km | kN | Ω/km |
| 6 | 13.2 | 7/1.55 | 4.65 | 36.2 | 4.18 | 2.5361 |
| 4 | 21.1 | 7/1.96 | 5.88 | 57.9 | 6.69 | 1.586 |
| 2 | 33.5 | 7/2.47 | 7.41 | 92 | 10.6 | 0.9987 |
| 1/0 | 53.5 | 7/3.12 | 9.36 | 146.8 | 17 | 0.62592 |
| 2/0 | 67.3 | 7/3.50 | 10.5 | 184.8 | 20.4 | 0.49738 |
| 3/0 | 84.9 | 7/3.93 | 11.79 | 233 | 25.7 | 0.3945 |
| 4/0 | 107 | 7/4.42 | 13.26 | 294.7 | 32.5 | 0.31188 |
| 250 | 126 | 19/2.91 | 14.55 | 346.7 | 38.8 | 0.26509 |
| 300 | 152 | 19/3.19 | 15.95 | 416.7 | 46.6 | 0.22059 |
| 350 | 178 | 19/3.45 | 17.25 | 487.3 | 52 | 0.1886 |
| 400 | 203 | 19/3.69 | 18.45 | 557.5 | 59.5 | 0.16486 |
| 450 | 228 | 19/3.91 | 19.55 | 626 | 66.8 | 0.14683 |
| 500 | 253 | 19/4.12 | 20.6 | 695 | 74.2 | 0.13224 |
| 550 | 279 | 37/3.10 | 21.7 | 766.2 | 83.9 | 0.11995 |
| 600 | 303 | 37/3.23 | 22.61 | 831.9 | 91 | 0.11049 |
| 650 | 330 | 37/3.37 | 23.59 | 905.5 | 94.9 | 0.1015 |
| 700 | 354 | 37/3.49 | 24.43 | 971.2 | 101 | 0.09464 |
| 750 | 381 | 37/3.62 | 25.34 | 1045 | 109 | 0.08796 |
| 800 | 404 | 37/3.73 | 26.11 | 1109 | 116 | 0.08285 |
| 900 | 456 | 37/3.96 | 27.72 | 1250 | 131 | 0.07351 |
| 1000 | 508 | 37/4.18 | 29.26 | 1393 | 146 | 0.06597 |
| 1250 | 631 | 61/3.63 | 32.67 | 1732 | 179 | 0.05306 |
| 1500 | 759 | 61/3.98 | 35.82 | 2082 | 215 | 0.04414 |
| 1750 | 886 | 61/4.30 | 38.7 | 2431 | 251 | 0.03781 |
| Code Name | Conductor Size | No. and Diameter | Overall Diameter | Mass | Rated Strength | Nominal DC Resistance at 20℃ | |
|---|---|---|---|---|---|---|---|
| MCM | mm² | mm | mm | kg/km | kN | Ω/km | |
| AKRON | 30.58 | 15.5 | 7/1.68 | 5.04 | 42.58 | 4.92 | 2.159 |
| ALTON | 48.69 | 24.7 | 7/2.12 | 6.36 | 67.8 | 7.83 | 1.356 |
| AMES | 77.47 | 39.2 | 7/2.67 | 8.01 | 107.5 | 12.4 | 0.8547 |
| AZUSA | 123.3 | 62.4 | 7/3.37 | 10.11 | 171.3 | 18.9 | 0.5365 |
| ANAHEIM | 155.4 | 78.6 | 7/3.78 | 11.34 | 215.6 | 23.8 | 0.4264 |
| AMHERST | 195.7 | 99.3 | 7/4.25 | 12.75 | 272.5 | 30 | 0.3373 |
| ALLIANCE | 246.9 | 125 | 7/4.77 | 14.31 | 343.2 | 37.8 | 0.2678 |
| BUTTE | 312.8 | 159 | 19/3.26 | 16.3 | 435.1 | 46.5 | 0.2112 |
| CANTON | 394.5 | 200 | 19/3.66 | 18.3 | 548.5 | 58.6 | 0.1676 |
| CAIRO | 465.4 | 236 | 19/3.98 | 19.9 | 648.6 | 69.2 | 0.1417 |
| DARIEN | 559.5 | 284 | 19/4.36 | 21.8 | 778.3 | 83.1 | 0.1181 |
| ELGIN | 652.4 | 331 | 19/4.71 | 23.55 | 908.3 | 97 | 0.1012 |
| FLINT | 740.8 | 375 | 37/3.59 | 25.13 | 1028 | 107 | 0.08944 |
| GREELEY | 927.2 | 470 | 37/4.02 | 28.14 | 1289 | 135 | 0.07133 |
| — | 1077.4 | 547 | 61/3.38 | 30.42 | 1502 | 156 | 0.0612 |
| — | 1165.1 | 590 | 61/3.51 | 31.59 | 1620 | 167 | 0.05675 |
| — | 1259.6 | 638 | 61/3.65 | 32.85 | 1751 | 181 | 0.05248 |
| — | 1348.8 | 685 | 61/3.78 | 34.02 | 1878 | 194 | 0.04893 |
| — | 1439.2 | 729 | 61/3.90 | 35.1 | 1999 | 207 | 0.04597 |
| AAAC | ||||||||
|---|---|---|---|---|---|---|---|---|
| Code | Old Code | Area | No. of Wires | Diameter | Mass per Unit Length | Rated Strength | DC Resistance | |
| Wire | Cond. | |||||||
| mm² | mm | mm | kg/km | kN | Ω/km | |||
| 16-AL3 | 16 | 15.9 | 7 | 1.7 | 5.1 | 43.4 | 4.69 | 2.0701 |
| 24-AL3 | 25 | 24.2 | 7 | 2.1 | 6.3 | 66.2 | 7.15 | 1.3566 |
| 34-AL3 | 35 | 34.4 | 7 | 2.5 | 7.5 | 93.8 | 10.14 | 0.9572 |
| 49-AL3 | 50 | 49.5 | 7 | 3 | 9 | 135.1 | 14.6 | 0.6647 |
| 48-AL3 | 50 | 48.3 | 19 | 1.8 | 9 | 132.7 | 14.26 | 0.6841 |
| 66-AL3 | 70 | 65.8 | 19 | 2.1 | 10.5 | 180.7 | 19.41 | 0.5026 |
| 93-AL3 | 95 | 93.3 | 19 | 2.5 | 12.5 | 256 | 27.51 | 0.3546 |
| 117-AL3 | 120 | 117 | 19 | 2.8 | 14 | 321.2 | 34.51 | 0.2827 |
| 147-AL3 | 150 | 147.1 | 37 | 2.25 | 15.8 | 405.3 | 43.4 | 0.2256 |
| 182-AL3 | 185 | 181.6 | 37 | 2.5 | 17.5 | 500.3 | 53.58 | 0.1827 |
| 243-AL3 | 240 | 242.5 | 61 | 2.25 | 20.3 | 670.3 | 71.55 | 0.1373 |
| 299-AL3 | 300 | 299.4 | 61 | 2.5 | 22.5 | 827.5 | 88.33 | 0.1112 |
| 400-AL3 | 400 | 400.1 | 61 | 2.89 | 26 | 1105.9 | 118.04 | 0.0832 |
| 500-AL3 | 500 | 499.8 | 61 | 3.23 | 29.1 | 1381.4 | 147.45 | 0.0666 |
| 626-AL3 | 625 | 626.2 | 91 | 2.96 | 32.6 | 1737.7 | 184.73 | 0.0534 |
| 802-AL3 | 800 | 802.1 | 91 | 3.35 | 36.9 | 2225.8 | 236.62 | 0.0417 |
| 1000-AL3 | 1000 | 999.7 | 91 | 3.74 | 41.1 | 2774.3 | 294.91 | 0.0334 |
| Code | Old code | Area | No.of Wires | Diameter | Mass per Unit Length | Rated Strength | DC Resistance | |
|---|---|---|---|---|---|---|---|---|
| Wire | Cond. | |||||||
| mm 2 | mm | mm | kg/km | kN | Ω/km | |||
| 19-AL3 | BOX | 18.8 | 7 | 1.85 | 5.55 | 51.4 | 5.55 | 1.748 |
| 24-AL3 | ACACIA | 23.8 | 7 | 2.08 | 6.24 | 64.9 | 7.02 | 1.3828 |
| 30-AL3 | ALMOND | 30.1 | 7 | 2.34 | 7.02 | 82.2 | 8.88 | 1.0926 |
| 35-AL3 | CEDAR | 35.5 | 7 | 2.54 | 7.62 | 96.8 | 10.46 | 0.9273 |
| 42-AL3 | DEODAR | 42.2 | 7 | 2.77 | 8.31 | 115.2 | 12.44 | 0.7797 |
| 48-AL3 | FIR | 47.8 | 7 | 2.95 | 8.85 | 130.6 | 14.11 | 0.6875 |
| 60-AL3 | HAZEL | 59.9 | 7 | 3.3 | 9.9 | 163.4 | 17.66 | 0.5494 |
| 72-AL3 | PINE | 71.6 | 7 | 3.61 | 10.8 | 195.6 | 21.14 | 0.4591 |
| 84-AL3 | HOLLY | 84.1 | 7 | 3.91 | 11.7 | 229.5 | 24.79 | 0.3913 |
| 90-AL3 | WILLOW | 89.7 | 7 | 4.04 | 12.1 | 245 | 26.47 | 0.3665 |
| 119-AL3 | OAK | 118.9 | 7 | 4.65 | 14 | 324.5 | 35.07 | 0.2767 |
| 151-AL3 | MULBERRY | 150.9 | 19 | 3.18 | 15.9 | 414.3 | 44.52 | 0.2192 |
| 181-AL3 | ASH | 180.7 | 19 | 3.48 | 17.4 | 496.1 | 53.31 | 0.183 |
| 211-AL3 | ELM | 211 | 19 | 3.76 | 18.8 | 579.2 | 62.24 | 0.1568 |
| 239-AL3 | POPLAR | 239.4 | 37 | 2.87 | 20.1 | 659.4 | 70.61 | 0.1387 |
| 303-AL3 | SYCAMORE | 303.2 | 37 | 3.23 | 22.6 | 835.2 | 89.4 | 0.1095 |
| 362-AL3 | UPAS | 362.1 | 37 | 3.53 | 24.7 | 997.5 | 106.82 | 0.0917 |
| 479-AL3 | YEW | 479 | 37 | 4.06 | 28.4 | 1319.6 | 141.31 | 0.0693 |
| 498-AL3 | TOTARA | 498.1 | 37 | 4.14 | 29 | 1372.1 | 146.93 | 0.0666 |
| 587-AL3 | RUBUS | 586.9 | 61 | 3.5 | 31.5 | 1622 | 173.13 | 0.0567 |
| 659-AL3 | SORBUS | 659.4 | 61 | 3.71 | 33.4 | 1822.5 | 194.53 | 0.0505 |
| 821-AL3 | ARAUCARIA | 821.1 | 61 | 4.14 | 37.3 | 2269.4 | 242.24 | 0.0406 |
| 996-AL3 | REDWOOD | 996.2 | 61 | 4.56 | 41 | 2753.2 | 293.88 | 0.0334 |
| AAAC/1120 | |||||||
|---|---|---|---|---|---|---|---|
| Code Name | Stranding and Wire Diameter | Approx.Overall Diameter | Cross-sectional Area | Approx. Mass | Calculated Breaking Load (CBL) | Equiv.Aluminium Area | D.C.Resistance at 20℃ |
| mm | mm | mm² | kg/km | KN | mm² | Ω/km | |
| Chlorine | 7/2.50 | 7.5 | 34.36 | 94.3 | 8.18 | 32.8 | 0.864 |
| Chromium | 7/2.75 | 8.25 | 41.58 | 113 | 9.91 | 39.7 | 0.713 |
| Fluorine | 7/3.00 | 9 | 49.48 | 135 | 11.8 | 47.2 | 0.599 |
| Helium | 7/3.75 | 11.3 | 77.28 | 211 | 17.6 | 73.7 | 0.383 |
| Hydrogen | 7/4.50 | 13.5 | 111.3 | 304 | 24.3 | 106 | 0.266 |
| lodine | 7/4.75 | 14.3 | 124 | 339 | 27.1 | 118 | 0.239 |
| Krypton | 19/3.25 | 16.3 | 157.6 | 433 | 37.4 | 150 | 0.189 |
| Lutetium | 19/3.50 | 17.5 | 182.8 | 503 | 41.7 | 173 | 0.163 |
| Neon | 19/3.75 | 18.8 | 209.8 | 576 | 47.8 | 199 | 0.142 |
| Nitrogen | 37/3.00 | 21 | 261.6 | 721 | 62.2 | 248 | 0.114 |
| Nobelium | 37/3.25 | 22.8 | 307 | 845 | 72.8 | 291 | 0.0973 |
| Oxygen | 19/4.75 | 23.8 | 336.7 | 924 | 73.6 | 320 | 0.0884 |
| Phosphorus | 37/3.75 | 26.3 | 408.5 | 1120 | 93.1 | 387 | 0.0731 |
| Selenium | 61/3.25 | 29.3 | 506.1 | 1400 | 114 | 478 | 0.0592 |
| Silicon | 61/3.50 | 31.5 | 586.9 | 1620 | 127 | 555 | 0.0511 |
| Sulfur | 61/3.75 | 33.8 | 673.4 | 1860 | 145 | 636 | 0.0444 |
| AAAC/6201 | |||||||
| Code Name | Stranding and Wire Diameter | Approx.Overall Diameter | Cross-sectional Area | Approx. Mass | Calculated Breaking Load (CBL) | Equiv.Aluminium Area | D.C.Resistance at 20℃ |
| mm | mm | mm² | kg/km | KN | mm² | Ω/km | |
| Diamond | 7/2.50 | 7.5 | 34.36 | 94.3 | 9.64 | 29.3 | 0.967 |
| Dolomite | 7/2.75 | 8.25 | 41.58 | 113 | 11.6 | 35.4 | 0.799 |
| Emerald | 7/3.00 | 9 | 49.48 | 135 | 13.9 | 42.2 | 0.671 |
| Garnet | 7/3.75 | 11.3 | 77.28 | 211 | 21.7 | 65.8 | 0.43 |
| Jade | 7/4.50 | 13.5 | 111.3 | 304 | 31.2 | 94.8 | 0.298 |
| Jasper | 7/4.75 | 14.3 | 124 | 339 | 34.8 | 106 | 0.268 |
| Opal | 19/3.25 | 16.3 | 157.6 | 433 | 44.2 | 134 | 0.212 |
| Patronite | 19/3.50 | 17.5 | 182.8 | 503 | 51.3 | 155 | 0.183 |
| Pearl | 19/3.75 | 18.8 | 209.8 | 576 | 58.8 | 178 | 0.159 |
| Ruby | 37/3.00 | 21 | 261.6 | 721 | 73.5 | 221 | 0.128 |
| Ruthenium | 37/3.25 | 22.8 | 307 | 845 | 86.1 | 260 | 0.109 |
| Rutile | 19/4.75 | 23.8 | 336.7 | 924 | 94.4 | 285 | 0.0991 |
| Sapphire | 37/3.75 | 26.3 | 408.5 | 1120 | 115 | 345 | 0.0819 |
| Spinel | 61/3.25 | 29.3 | 506.1 | 1400 | 135 | 427 | 0.0662 |
| Tantalum | 61/3.50 | 31.5 | 586.9 | 1620 | 156 | 495 | 0.0572 |
| Topaz | 61/3.75 | 33.8 | 673.4 | 1860 | 179 | 568 | 0.0498 |
| AAAC(JLHA1,JLHA2) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Code Number | Area | No. of Wires | Diameter | Linear Mass | Rated strength | D.C. Resistance at 20℃ | |||
| Wire | Cond. | JLHA1 | JLHA2 | JLHA1 | JLHA2 | ||||
| mm² | mm | kg/km | kN | Ω/km | |||||
| 16 | 16.1 | 7 | 1.71 | 5.13 | 44 | 5.22 | 4.74 | 2.0695 | 2.05 |
| 20 | 18.4 | 7 | 1.83 | 5.49 | 50.4 | 5.98 | 5.43 | 1.807 | 1.79 |
| 25 | 24.9 | 7 | 2.13 | 6.39 | 68.3 | 8.11 | 7.36 | 1.3339 | 1.3213 |
| 30 | 28.8 | 7 | 2.29 | 6.87 | 79 | 9.37 | 8.51 | 1.154 | 1.1431 |
| 35 | 34.9 | 7 | 2.52 | 7.56 | 95.6 | 11.35 | 10.3 | 0.9529 | 0.9439 |
| 45 | 45.9 | 7 | 2.89 | 8.67 | 125.7 | 14.92 | 13.55 | 0.7246 | 0.7177 |
| 50 | 50.1 | 7 | 3.02 | 9.06 | 137.3 | 16.3 | 14.79 | 0.6635 | 0.6573 |
| 70 | 70.1 | 7 | 3.57 | 10.7 | 191.9 | 22.07 | 20.67 | 0.4748 | 0.4703 |
| 75 | 72.4 | 7 | 3.63 | 10.9 | 198.4 | 22.82 | 21.37 | 0.4593 | 0.4549 |
| 95 | 95.1 | 7 | 4.16 | 12.5 | 260.5 | 29.97 | 28.07 | 0.3497 | 0.3464 |
| 120 | 115 | 19 | 2.78 | 13.9 | 317.3 | 37.48 | 34.02 | 0.2899 | 0.2871 |
| 145 | 143 | 19 | 3.1 | 15.5 | 294.6 | 46.61 | 42.3 | 0.2331 | 0.2309 |
| 150 | 150 | 19 | 3.17 | 15.9 | 412.6 | 48.74 | 44.24 | 0.2229 | 0.2208 |
| 185 | 184 | 19 | 3.51 | 17.6 | 505.9 | 57.91 | 54.24 | 0.1818 | 0.1801 |
| 210 | 210 | 19 | 3.75 | 18.8 | 577.4 | 66.1 | 61.91 | 0.1593 | 0.1578 |
| 230 | 230 | 19 | 3.93 | 19.7 | 634.2 | 72.6 | 67.99 | 0.1451 | 0.1437 |
| 240 | 240 | 19 | 4.01 | 20.1 | 660.3 | 75.59 | 70.79 | 0.1393 | 0.138 |
| 300 | 299 | 37 | 3.21 | 22.5 | 825.9 | 97.32 | 88.33 | 0.1119 | 0.1109 |
| 360 | 362 | 37 | 3.53 | 24.7 | 998.8 | 114.1 | 106.8 | 0.0925 | 0.0917 |
| 400 | 400 | 37 | 3.71 | 26 | 1103.2 | 126 | 118 | 0.0838 | 0.083 |
| 465 | 460 | 37 | 3.98 | 27.9 | 1269.6 | 145 | 135.8 | 0.0728 | 0.0721 |
| 500 | 500 | 37 | 4.15 | 29.1 | 1380.4 | 157.7 | 147.6 | 0.067 | 0.0663 |
| 520 | 518 | 37 | 4.22 | 29.5 | 1427.4 | 163 | 152.7 | 0.0648 | 0.0641 |
| 580 | 575 | 37 | 4.45 | 31.2 | 1587.2 | 181.3 | 169.8 | 0.0582 | 0.0577 |
| 630 | 631 | 61 | 3.63 | 32.7 | 1743.8 | 198.9 | 186.2 | 0.0532 | 0.0527 |
| AAAC(JLHA1, JLHA2) | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Code Number | Area | No. of Wires | Diameter | Linear Mass | Rated strength | D.C. Resistance at 20℃ | ||||||
| Wire | Cond. | JLHA1 | JLHA2 | JLHA1 | JLHA2 | |||||||
| mm² | mm | kg/km | kN | Ω/km | ||||||||
| 650 | 645 | 61 | 3.67 | 33 | 1782.4 | 203.3 | 190.4 | 0.052 | 0.0515 | |||
| 720 | 725 | 61 | 3.89 | 35 | 2002.5 | 228.4 | 213.9 | 0.0463 | 0.0459 | |||
| 800 | 801 | 61 | 4.09 | 36.8 | 2213.7 | 252.5 | 236.4 | 0.0419 | 0.0415 | |||
| 825 | 817 | 61 | 4.13 | 37.2 | 2257.2 | 257.4 | 241.1 | 0.0411 | 0.0407 | |||
| 930 | 919 | 61 | 4.38 | 39.4 | 2538.8 | 289.5 | 271.1 | 0.0365 | 0.0362 | |||
| 1000 | 1001 | 61 | 4.57 | 41.1 | 2763.8 | 315.2 | 295.2 | 0.0335 | 0.0332 | |||
| 1050 | 1037 | 91 | 3.81 | 41.9 | 2868.8 | 310.5 | 290.8 | 0.0324 | 0.0321 | |||
| 1150 | 1161 | 91 | 4.03 | 44.3 | 3209.7 | 347.4 | 325.3 | 0.0289 | 0.0287 | |||
| 1300 | 1291 | 91 | 4.25 | 46.8 | 3569.7 | 386.3 | 361.8 | 0.026 | 0.0258 | |||
| 1450 | 1441 | 91 | 4.49 | 49.4 | 3984.2 | 431.2 | 403.8 | 0.0233 | 0.0231 | |||
| AAAC(JLHA3,JLHA4) | |||||||||
|---|---|---|---|---|---|---|---|---|---|
| Code Number | Area | No. of Wires | Diameter | Linear Mass | Rated strength | D.C. Resistance at 20℃ | |||
| Wire | Cond. | JLHA3 | JLHA4 | JLHA3 | JLHA4 | ||||
| mm² | mm | kg/km | kN | Ω/km | |||||
| 25 | 24.9 | 7 | 2.13 | 6.39 | 68.3 | 6.24 | 7.23 | 1.1971 | 1.2285 |
| 35 | 34.4 | 7 | 2.5 | 7.5 | 94.1 | 8.59 | 9.96 | 0.8689 | 0.8918 |
| 40 | 40.1 | 7 | 2.7 | 8.1 | 109.8 | 10.02 | 11.62 | 0.745 | 0.7646 |
| 50 | 49.5 | 7 | 3 | 9 | 135.5 | 11.88 | 13.61 | 0.6034 | 0.6193 |
| 70 | 71.3 | 7 | 3.6 | 10.8 | 195.1 | 17.1 | 18.88 | 0.4191 | 0.4301 |
| 95 | 95.1 | 7 | 4.16 | 12.5 | 260.5 | 21.88 | 24.26 | 0.3138 | 0.3221 |
| 100 | 100 | 19 | 2.59 | 13 | 275.4 | 25.03 | 29.03 | 0.2997 | 0.3076 |
| 120 | 121 | 19 | 2.85 | 14.3 | 333.5 | 30.3 | 35.15 | 0.2475 | 0.254 |
| 125 | 125 | 19 | 2.89 | 14.5 | 343 | 31.16 | 36.14 | 0.2407 | 0.2471 |
| 150 | 148 | 19 | 3.15 | 15.8 | 407.4 | 35.54 | 40.72 | 0.2026 | 0.208 |
| 185 | 183 | 19 | 3.5 | 17.5 | 503 | 43.87 | 48.44 | 0.1641 | 0.1684 |
| 200 | 200 | 19 | 3.66 | 18.3 | 550 | 47.98 | 52.97 | 0.1501 | 0.154 |
| 210 | 210 | 19 | 3.75 | 18.8 | 577.4 | 50.36 | 55.61 | 0.143 | 0.1467 |
| 240 | 239 | 19 | 4 | 20 | 657 | 54.92 | 60.88 | 0.1257 | 0.129 |
| 250 | 250 | 19 | 4.09 | 20.5 | 686.9 | 57.41 | 63.65 | 0.1202 | 0.1234 |
| 275 | 276 | 37 | 3.08 | 21.6 | 760.3 | 66.16 | 75.81 | 0.1091 | 0.112 |
| 280 | 279 | 37 | 3.1 | 21.7 | 770.2 | 67.02 | 76.8 | 0.1077 | 0.1105 |
| 300 | 298 | 37 | 3.2 | 22.4 | 820.7 | 71.42 | 81.83 | 0.1011 | 0.1037 |
| 315 | 315 | 37 | 3.29 | 23 | 867.6 | 75.49 | 86.5 | 0.0956 | 0.0981 |
| 335 | 336 | 37 | 3.4 | 23.8 | 926.5 | 80.62 | 92.38 | 0.0895 | 0.0919 |
| 340 | 340 | 37 | 3.42 | 23.9 | 937.5 | 81.57 | 93.47 | 0.0885 | 0.0908 |
| 400 | 400 | 37 | 3.71 | 26 | 1103.2 | 96 | 106 | 0.0752 | 0.0772 |
| 425 | 426 | 37 | 3.83 | 26.8 | 1175.7 | 102.3 | 113 | 0.0705 | 0.0724 |
| 450 | 451 | 37 | 3.94 | 27.6 | 1244.2 | 108.3 | 119.5 | 0.0667 | 0.0684 |
| 500 | 503 | 37 | 4.16 | 29.1 | 1387.1 | 115.7 | 128.2 | 0.0598 | 0.0614 |
| 530 | 531 | 61 | 3.33 | 30 | 1467.4 | 127.5 | 146.1 | 0.0567 | 0.0582 |
| 560 | 560 | 37 | 4.39 | 30.7 | 1544.7 | 128.8 | 142.8 | 0.0537 | 0.0551 |
| 630 | 631 | 61 | 3.63 | 32.7 | 1743.8 | 151.5 | 167.3 | 0.0477 | 0.049 |
| 675 | 674 | 61 | 3.75 | 33.8 | 1861 | 161.7 | 178.5 | 0.0447 | 0.0459 |
| 710 | 710 | 61 | 3.85 | 34.7 | 1961.5 | 170.4 | 188.2 | 0.0424 | 0.0435 |
| 775 | 774 | 91 | 3.29 | 36.2 | 2139.2 | 176.4 | 202.1 | 0.039 | 0.04 |
| 800 | 801 | 61 | 4.09 | 36.8 | 2213.7 | 184.3 | 204.4 | 0.0376 | 0.0386 |
| 870 | 871 | 91 | 3.49 | 38.4 | 2407.2 | 198.5 | 227.4 | 0.0346 | 0.0355 |
| 900 | 898 | 61 | 4.33 | 39 | 2481.1 | 206.6 | 229.1 | 0.0335 | 0.0344 |
| 940 | 937 | 91 | 3.62 | 39.8 | 2589.8 | 213.5 | 235.8 | 0.0322 | 0.033 |
| 975 | 973 | 91 | 3.69 | 40.6 | 2691 | 221.9 | 245 | 0.031 | 0.0318 |
| 1000 | 1001 | 61 | 4.57 | 41.1 | 2763.8 | 230.1 | 255.1 | 0.0301 | 0.0309 |
| 1080 | 1082 | 91 | 3.89 | 42.8 | 2990.6 | 246.6 | 272.3 | 0.0279 | 0.0286 |
| 1120 | 1121 | 91 | 3.96 | 43.6 | 3099.2 | 255.5 | 282.2 | 0.0269 | 0.0276 |
| 1215 | 1213 | 91 | 4.12 | 45.3 | 3354.7 | 265.1 | 293.9 | 0.0249 | 0.0255 |
| 1250 | 1249 | 91 | 4.18 | 46 | 3453.1 | 272.9 | 302.5 | 0.0241 | 0.0248 |
| 1350 | 1352 | 91 | 4.35 | 47.9 | 3739.7 | 295.5 | 327.6 | 0.0223 | 0.0229 |
| 1400 | 1403 | 91 | 4.43 | 48.7 | 3878.5 | 306.5 | 339.8 | 0.0215 | 0.0221 |
| 1500 | 1499 | 91 | 4.58 | 50.4 | 4145.6 | 327.6 | 363.2 | 0.0201 | 0.0206 |
| 1645 | 1647 | 91 | 4.8 | 52.8 | 4553.4 | 359.8 | 398.9 | 0.0183 | 0.0188 |
Before you specify
What information should I include in an inquiry?
Include the product designation, operating voltage, conductor size, number of cores, required length and delivery destination. Add installation conditions and any required standard.
Can I use these tables to make the final cable selection?
Use the published values to compare products. Confirm the final construction, current rating and installation requirements with your project engineer and the supplier.